Alarm Lock DL1200 Manuale delle Istruzioni Pagina 2

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 8
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 1
2
MOUNTING AND INSTALLATION
For factory prepped doors, use dimensions shown. Di-
mensions are referenced from center of 1¼" cylinder hole.
The Adams Rite
®
lock determines the backset.
When mounting the new Adams Rite
®
locks:
Do not install the outside cylinder -- this trim replaces it;
Do not install the faceplate (access to the cylinder set
screw in the lock is required during mounting and instal-
lation).
Mechanical Override Cylinder Cams
The DL1200 and DL/PDL1300 trim requires the use of an
oval Alarm Lock cam (supplied with cylinder). For other
manufacturers, please see the charts below.
Cylinder Collars:
The DL1200 and DL/PDL1300 can use a 1-" & 1¼" mor-
tise cylinder without the use of a collar (1¼" requires two
plastic spacers, supplied). For cylinders longer than 1¼" a
collar is required.
Order collars from an Alarm Lock distributor.
Template (use WI1459)
Corbin-Russwin HW1344
Marks HW1346
Arrow HW1348
Schlage HW1349
Cams for Standard Mortise Cylinders
Sargent HW1348
Cams for IC Mortise Cylinders
Best* HW1343
Corbin-Russwin HW1345
Medeco HW1347
Schlage HW1350
Yale HW1351
*Will be supplied together with Best IC Housing (HW1352)
Cylinder Length Collar P/N
1- HW1331
1-½ HW1342
Cam for Mechanical Override Cylinder
Backset is determined by
the Adams Rite lock
Vedere la pagina 1
1 2 3 4 5 6 7 8

Commenti su questo manuale

Nessun commento